Solar Battery Calculator: Capacity & Backup Runtime
Calculate the exact battery bank capacity in Ah and kWh required to power your home during electricity outages. Compare tall tubular and lithium (LiFePO4) battery configurations, 10-year replacement costs, and the solar panels needed to recharge your bank.
Appliance
Energy Storage & Backup Simulator
NASA PSH Data & DISCOM Tariff Engine
+ Add appliance
Choose a preset above or add appliances to calculate required battery capacity.
Your Battery Bank Estimate
12V 150Ah Battery Units
in series • parallel string(s)
- Required Capacity
- Ah kWh Nominal
- Usable Energy Storage
- kWh % safe DoD
- Initial Battery Cost Approx initial price
- Typical Lifespan
- years ~ cycles
- Continuous DC Current
- A
Continuous discharge current drawn by inverter from the battery bank at peak load.
Solar Panels Needed for Daytime Recharging
Fully recharges kWh in ~h daylight.
Recharging with solar panels saves 100% of this recurring electricity bill cost.
Already have an inverter battery installed?
Calculate exactly how many hours and minutes your existing battery will run your appliances:
Use Battery Runtime Calculator →Compare 3 Quotes from Verified PM Surya Ghar Installers
Get competitive pricing from DISCOM-empanelled local solar contractors. Free site inspection and complete net-metering assistance.
Compare battery types: C10 Solar Tubular vs LiFePO4 vs Lead-Acid
While flat plate lead-acid and tall tubular batteries carry a lower initial purchase price, lithium batteries provide twice the depth of discharge, zero acid maintenance, and eliminate replacement costs over a 10-year period.
| Type | Usable Energy | Batteries (150Ah) | Initial Cost | Cycle Life | Lifespan | 10-Year Total Cost |
|---|---|---|---|---|---|---|
| kWh | units | cycles (% DoD) |
Assumptions & Technical Methodology Component benchmarks updated: 18 Nov 2026
- Battery bank is built from standard 12V 150Ah units — series count sets system voltage (12V, 24V, or 48V), parallel count sets ampere-hour capacity.
- Depth of discharge (DoD) limits applied: flat plate lead-acid 50%, C10 tall tubular 60%, and Lithium Iron Phosphate (LiFePO4) 85% to protect cycle longevity.
- A 95% inverter efficiency conversion loss is applied when converting DC battery energy to 230V single-phase AC household electricity.
- Solar panel recharge sizing assumes an 80% system balance-of-system (BOS) efficiency factoring in temperature derating, dust, and charge controller losses.
- 10-Year Lifecycle Cost accounts for replacement battery sets required based on rated cycle life plus regular distilled water maintenance for lead-acid/tubular.
Get Off-Grid Solar & Battery Storage Sizing Report Power Backup & Storage Requirements Enter 6-Digit SMS Verification Code
Enter your details to calculate customized off-grid battery bank capacity and backup runtime estimates. Just a few quick technical details to generate your customized engineering feasibility report. 6-digit SMS verification code sent to: +91
Calculation based on MNRE PM Surya Ghar subsidy guidelines. By continuing, you agree to receive customized solar quotes.
Battery Bank Size — 4-Hour Backup by Load
| Load | Capacity needed (lithium) |
|---|---|
| 1BHK (~300W) | 132 Ah |
| 2BHK (~600W) | 263 Ah |
| 3BHK (~1000W) | 439 Ah |
| 3BHK + AC (~2200W) | 965 Ah |
Lithium sizing shown as it needs the smallest bank; lead-acid/tubular need roughly 1.3–1.6× the capacity for the same backup.
How Solar Battery Sizing Works in India
Calculating the right battery bank size for an Indian home requires balancing peak power in Watts, total energy in Watt-hours, and the physical limits of battery chemistry. Many buyers make the mistake of buying an undersized 150Ah single battery for heavy loads, leading to rapid voltage drop, inverter tripping, and premature battery failure.
Inverter batteries in India are rated in Ampere-hours (Ah) at 12 Volts. A single 12V 150Ah battery has a nominal capacity of 1,800 Watt-hours (1.8 kWh). However, because a lead-acid or tubular battery should never be discharged below 50% to 60% of its capacity, only about 900 to 1,080 Watt-hours (approximately 1 unit of electricity) is actually usable. In contrast, modern Lithium Iron Phosphate (LiFePO4) batteries safely allow up to 85% to 90% depth of discharge.
Why C10 Solar Tubular Batteries Outperform C20 Inverter Batteries
A critical specification often overlooked by homeowners is the battery C-rating. Standard home inverter batteries sold in local retail shops are C20 rated, designed to be discharged slowly over 20 hours. When connected to solar panels, the charging current from a solar charge controller is often 20 to 40 Amperes, which causes C20 plates to overheat and shed active material. Solar tubular batteries are specifically manufactured as C10 rated under Indian Standard IS 16270, using thicker spine plates that handle rapid solar charging and high discharge currents effortlessly.
Choosing the Right Voltage: 12V, 24V, or 48V
Selecting the correct battery bank voltage is essential for electrical safety and energy efficiency. According to Ohm's law and Joule heating (I²R losses), running a 2,000-Watt load on a 12V battery forces more than 180 Amperes of direct current through the inverter cables. This requires extremely thick 35 to 50 sq.mm copper cables and causes substantial heat loss. By increasing the bank voltage to 24V (2 batteries in series), current is cut in half to 90 Amperes. For homes running air conditioners, water pumps, or whole-house loads above 2,200 Watts, a 48V system (4 batteries in series or a 48V/51.2V lithium rack) is the professional engineering standard.
How Many Solar Panels Are Needed to Recharge Your Battery?
A battery bank is only as reliable as the solar generation available to recharge it the following morning. In most parts of India, average annual Peak Sun Hours (PSH) range from 4.2 hours in eastern and northeastern states like West Bengal and Assam, to over 5.4 hours in western and central states like Rajasthan, Gujarat, and Maharashtra. To recharge a 5 kWh usable battery bank within 4.5 hours of peak daylight, approximately 1.4 kW of solar panels (three 540W Mono PERC panels) are needed after accounting for dust, temperature, and wiring derating factors.
10-Year Total Cost of Ownership: Tubular vs Lithium (LiFePO4)
While Lithium LiFePO4 batteries have a higher initial purchase price, they deliver 3,500 to 5,000 charge cycles, easily lasting 10 to 12 years without a single battery replacement. Over the same 10-year period, a flat plate lead-acid bank will need replacement 3 to 4 times, and a tall tubular bank will need replacement at least twice, alongside regular distilled water top-ups. When factoring in lifetime cycle cost per kilowatt-hour, lithium is comparable or cheaper than lead-acid, while occupying 70% less floor space.
Indian Regulatory & Safety Standards Referenced
- Bureau of Indian Standards (BIS) IS 16270: Secondary cells and batteries for solar photovoltaic application
- BIS IS 16046 / IEC 62133: Secondary cells containing alkaline or other non-acid electrolytes for energy storage
- Ministry of New and Renewable Energy (MNRE): Technical specifications for decentralized solar storage systems
Continue Planning Your Solar Setup
Solar Load Calculator
Calculate your total daily household electricity usage in units.
Inverter Size Calculator
Find the right VA and kVA inverter rating to pair with your battery bank.
Battery Runtime Calculator
Determine exact backup runtime in hours for an existing battery and connected load.
Hybrid Solar Calculator
Explore complete solar rooftop systems combining grid export with battery storage.
Explore Rooftop Solar by State & City
Calibrated with state Discom tariffs, local net-metering policies, and PM Surya Ghar subsidies across India.
Browse Solar Guides by State
Top Solar MarketsFrequently Asked Questions
Which battery type is best for solar backup in India: lead-acid, tall tubular, or lithium? ↓
Lithium Iron Phosphate (LiFePO4) is the best overall choice for solar installations. It costs more upfront but lasts 10 to 12 years (3,500 to 5,000 cycles), requires zero maintenance, charges in 2 to 3 hours, and delivers 85% to 90% usable capacity. Tall tubular C10 batteries are the popular budget choice, offering 4 to 5 years of service with 60% usable capacity and quarterly distilled water top-ups. Flat plate lead-acid batteries are not recommended for solar applications due to their short 2 to 3 year lifespan.
What is Depth of Discharge (DoD) and why does it change battery sizing? ↓
Depth of Discharge (DoD) represents the percentage of a battery's capacity that can be used before recharging without damaging the cell chemistry. Discharging tubular batteries beyond 60% causes accelerated sulfation and reduces lifespan. Lithium batteries safely support 85% to 90% discharge. Consequently, to deliver 3 kWh of actual backup, a tubular battery bank must be sized at 5.5 kWh nominal capacity, whereas a lithium bank needs only 3.5 kWh.
How many batteries do I need to run a 1.5 Ton Inverter AC during power cuts? ↓
A 1.5 Ton 5-star Inverter AC consumes approximately 1,100 to 1,300 Watts in continuous running mode (after initial cooling). To run the AC along with 2 ceiling fans and lights for 4 hours requires roughly 5.5 to 6.0 kWh of usable energy. This requires a 48V battery bank consisting of four 12V 150Ah tall tubular batteries, or a single 48V 100Ah (5.12 kWh) lithium battery pack paired with a minimum 3.5 kVA or 5 kVA inverter.
What is the difference between a C10 solar battery and a C20 normal inverter battery? ↓
The C-rating designates how quickly a battery can discharge its full capacity. A C20 battery is rated for a 20-hour slow discharge, typical of traditional home inverters. A C10 solar battery (IS 16270 certified) is engineered with heavier lead spine plates to handle deep discharge and rapid recharge in 10 hours or less. Using a C20 battery with solar panels results in overheating, water loss, and plate degradation because solar charge currents are much higher than grid trickle chargers.
Can I recharge my home backup battery bank entirely with solar panels? ↓
Yes. By connecting a solar charge controller (MPPT or PWM) or using a solar hybrid inverter, your solar panel array charges the battery bank during daytime sunlight. At nighttime or during grid outages, the inverter draws energy from the battery bank. In sunny states like Rajasthan, Gujarat, and Maharashtra, a 1.5 kW to 2 kW solar rooftop array fully recharges a 48V 150Ah battery bank in 4 to 5 hours.
Why does system voltage (12V vs 24V vs 48V) matter for inverter batteries? ↓
System voltage determines the direct current (Amperes) flowing between the battery and the inverter. Power equals Voltage times Current (Watts = Volts x Amps). For a 2,400-Watt load, a 12V system draws 200 Amperes, creating extreme heat, cable resistance, and fire risk. At 48V, the current drops to 50 Amperes, allowing safer operation, smaller cable thickness, and higher electrical conversion efficiency.
Does the PM Surya Ghar Muft Bijli Yojana subsidy cover batteries? ↓
The central PM Surya Ghar Muft Bijli Yojana subsidy of up to ₹78,000 is specifically designated for grid-tied (on-grid) rooftop solar systems. Standard battery banks and off-grid inverters are not covered under the central subsidy. However, you can install a grid-tied system with subsidy and add an AC-coupled battery storage system or install an approved hybrid system where state policies permit.
Can I connect old and new batteries together in the same battery bank? ↓
No. You should never mix old and new batteries, nor batteries of different capacities or chemistries (such as mixing tubular with lithium). The older battery will have higher internal resistance and lower capacity, causing the newer battery to continuously discharge into the older unit, leading to premature failure of the entire bank.