Solar Load Calculator: Home Appliance Energy Use
Add the appliances you run at home with how many you have and hours used per day. We will calculate your total daily and monthly electricity consumption, peak startup surge, recommended inverter rating, battery backup, and solar PV system size.
Select Your State & District
Electricity tariffs and state subsidy grants depend directly on your DISCOM and local solar irradiance.
Please select your state before proceeding
Home Appliances & Daily Usage Hours
Tell us what you know. Our engineering engine derives panel wattage, sun hours, and sizing behind the scenes.
Terrace Structure & System Preferences
Select your mounting structure to retain full terrace usability for walking and household activities.
Solar Load & Connected Inverter Engine
Wattage Duty Cycles & Surge Factor Model
Unlock Your Detailed Solar Report
Enter your 10-digit mobile number to view the itemized price breakdown, PM Surya Ghar subsidy deduction, and engineering report.
6-digit SMS code sent to: +91
Calculation based on MNRE PM Surya Ghar subsidy guidelines. By continuing, you agree to receive customized solar quotes.
Down from ₹ to basic DISCOM grid charges of ₹.
Total Turnkey - Subsidy .
Your recommended solar capacity ( kW) is higher than your current sanctioned load ( kW). Most DISCOMs require solar capacity to match or be lower than the sanctioned load. You can easily apply for a load enhancement online on your DISCOM portal.
Itemized Turnkey Cost Breakdown
MNRE BenchmarksSystem Size Comparison (2 kW vs 3 kW vs 5 kW)
← Swipe →| Capacity | Monthly Gen | Subsidy | Net Cost | Savings/Mo |
|---|---|---|---|---|
| Optimal | ~ units |
Get 3 Free Quotes from PM Surya Ghar Empanelled Installers
DISCOM-approved contractors in provide free physical site inspection, shadow feasibility report, and complete net-metering liaison.
Assumptions used Data updated: 18 Nov 2026
- Wattage figures are typical Indian household ratings — actual appliances may vary by brand.
- Peak load includes a surge/starting-current factor for motors and compressors (fans, ACs, pumps, fridges).
- Recommended solar size assumes daily consumption repeats every day of the month.
- Inverter capacity is computed using a 0.8 inductive power factor and an industry-standard 25% continuous overhead buffer.
- Battery storage estimates account for depth of discharge (60% for tubular lead-acid, 80% for lithium ferro-phosphate) and 85% inverter conversion efficiency.
Unlock Your Detailed Solar Report & Subsidy Breakdown Customize Your Rooftop Solar Preferences Enter 6-Digit SMS Verification Code
Enter your contact details to view itemized price breakdowns, PM Surya Ghar subsidy deductions, and engineering feasibility. Just a few quick technical details to generate your customized engineering feasibility report. 6-digit SMS verification code sent to: +91
Calculation based on MNRE PM Surya Ghar subsidy guidelines. By continuing, you agree to receive customized solar quotes.
Typical Indian Household Electrical Load Benchmarks
Electric consumption varies significantly across Indian homes depending on climate, floor space, and the presence of heavy inductive motor loads like air conditioners and water pumps. Here is how standard Indian residential configurations compare in continuous connected load, peak startup surge, and solar PV capacity requirements:
| Home Profile | Daily Units (kWh) | Connected Load | Peak Surge | Inverter Size | Battery Bank | Recommended Solar |
|---|---|---|---|---|---|---|
| 1 BHK Flat (Fans, Lights, TV, Fridge) | 4.5 - 6.0 units | 450 W | 1,100 W | 1.1 kVA | 150 Ah (12V) | 1.5 kW |
| 2 BHK Standard (+ 1 Inverter AC, Washing Machine) | 10.0 - 14.0 units | 2,250 W | 4,800 W | 3.5 kVA | 2x 150 Ah (24V) | 3.0 kW |
| 3 BHK (+ 2 Inverter ACs, Geyser, Water Pump) | 18.0 - 24.0 units | 5,800 W | 11,500 W | 7.5 kVA | 4x 150 Ah (48V) | 5.0 kW |
| 4 BHK / Villa (3+ ACs, Geysers, Modern Kitchen) | 28.0 - 38.0 units | 8,500 W | 16,000 W | 10 kVA | 4x 200 Ah (48V) | 8.0 kW |
Typical Household Load — What Do You Need?
| Home profile | Daily units | Recommended size |
|---|---|---|
| 1BHK — fans, lights, TV, fridge | 5.1 | 1.5 kW |
| 2BHK — + washing machine, 1 AC | 15.7 | 4.5 kW |
| 3BHK — + 2 AC, geyser | 33.4 | 9.5 kW |
Sample profiles for common Indian homes. Add your own appliances above for an exact figure.
How Solar Load Calculation Works: Electrical Engineering Formulas
Accurate solar sizing prevents two costly mistakes: undersizing (which forces you to buy expensive peak grid electricity) and oversizing (which locks away capital unnecessarily). Here are the exact engineering formulas used by solar engineers and our calculation engine:
1. Daily Electrical Energy Consumption (Watt-Hours)
Every appliance consumes power over time. Total daily consumption is calculated by summing the rated wattage, quantity, and daily operating hours for each connected device:
2. Inverter / PCU Rating in Volt-Amperes (VA)
Inverters are rated in apparent power (VA or kVA), not active power (Watts). Inductive loads like ceiling fans, refrigerator compressors, and air conditioner motors cause a phase shift between voltage and current, typically resulting in a 0.8 power factor. To prevent breaker trips when heavy appliances kick in, engineers apply a 25% safety margin:
3. Solar PV Capacity Sizing (kW)
Solar panel capacity depends on your monthly electrical demand, your location Peak Sun Hours (PSH), and the system Performance Ratio (PR ~ 78% accounting for thermal derating, inverter DC-to-AC conversion, and wiring resistance):
4. Battery Bank Storage Capacity (Ampere-Hours)
For off-grid and hybrid backup systems, battery capacity in Ampere-Hours (Ah) must account for the system DC bus voltage (12V, 24V, or 48V), inverter conversion efficiency (85%), and usable Depth of Discharge (DoD):
Appliance Power Consumption & Inverter Surge Database
Refer to our database of 36 common Indian household electrical appliances. The starting surge factor indicates the brief inrush current required by electric motors during compressor or rotor acceleration:
| Appliance | Category | Rated Running Power | Surge Multiplier | Peak Startup Watts | Typical Indian Usage |
|---|---|---|---|---|---|
| LED Bulb | lighting | 9 W | 1x | 9 W | 5 - 6 hrs |
| Tube Light | lighting | 20 W | 1x | 20 W | 5 - 6 hrs |
| CFL | lighting | 15 W | 1x | 15 W | 5 - 6 hrs |
| Ceiling Fan | cooling | 75 W | 1.5x | 113 W | 8 - 12 hrs |
| Table Fan | cooling | 50 W | 1.5x | 75 W | 8 - 12 hrs |
| Air Cooler | cooling | 180 W | 2x | 360 W | 8 - 12 hrs |
| AC 1 Ton (3 Star) | cooling | 1100 W | 3x | 3300 W | 6 - 8 hrs |
| AC 1 Ton Inverter (5 Star) | cooling | 850 W | 1.8x | 1530 W | 8 - 12 hrs |
| AC 1.5 Ton (3 Star) | cooling | 1700 W | 3x | 5100 W | 6 - 8 hrs |
| AC 1.5 Ton Inverter | cooling | 1300 W | 2x | 2600 W | 6 - 8 hrs |
| AC 1.5 Ton Inverter (5 Star) | cooling | 1050 W | 1.8x | 1890 W | 6 - 8 hrs |
| AC 2 Ton | cooling | 2100 W | 3x | 6300 W | 6 - 8 hrs |
| AC 2 Ton Inverter (5 Star) | cooling | 1550 W | 1.8x | 2790 W | 6 - 8 hrs |
| Refrigerator 200L | kitchen | 150 W | 3x | 450 W | 24 hrs |
| Refrigerator 300L | kitchen | 200 W | 3x | 600 W | 24 hrs |
| Refrigerator 500L | kitchen | 300 W | 3x | 900 W | 24 hrs |
| Microwave Oven | kitchen | 1200 W | 1x | 1200 W | 0.5 - 1 hr |
| Mixer Grinder | kitchen | 500 W | 2x | 1000 W | 1 - 2 hrs |
| Induction Cooktop | kitchen | 1800 W | 1x | 1800 W | 0.5 - 1 hr |
| Electric Kettle | kitchen | 1500 W | 1x | 1500 W | 0.5 - 1 hr |
| Water Purifier | kitchen | 25 W | 1x | 25 W | 24 hrs |
| LED TV 32 inch | entertainment | 50 W | 1x | 50 W | 4 - 6 hrs |
| LED TV 43 inch | entertainment | 80 W | 1x | 80 W | 4 - 6 hrs |
| LED TV 55 inch | entertainment | 120 W | 1x | 120 W | 4 - 6 hrs |
| Set-top Box | entertainment | 25 W | 1x | 25 W | 4 - 6 hrs |
| WiFi Router | electronics | 10 W | 1x | 10 W | 12 - 24 hrs |
| Laptop | electronics | 65 W | 1x | 65 W | 4 - 8 hrs |
| Desktop Computer | electronics | 200 W | 1x | 200 W | 4 - 8 hrs |
| Mobile Charger | electronics | 10 W | 1x | 10 W | 12 - 24 hrs |
| CCTV with DVR | electronics | 30 W | 1x | 30 W | 12 - 24 hrs |
| Air Purifier | electronics | 50 W | 1x | 50 W | 4 - 8 hrs |
| Washing Machine | appliances | 500 W | 2x | 1000 W | 1 - 2 hrs |
| Iron | appliances | 1000 W | 1x | 1000 W | 1 - 2 hrs |
| Vacuum Cleaner | appliances | 800 W | 2x | 1600 W | 1 - 2 hrs |
| Sewing Machine | appliances | 100 W | 1.5x | 150 W | 1 - 2 hrs |
| Geyser 15L | appliances | 2000 W | 1x | 2000 W | 0.5 - 1 hr |
| Water Pump 0.5 HP | appliances | 400 W | 3x | 1200 W | 1 - 2 hrs |
| Water Pump 1 HP | appliances | 750 W | 3x | 2250 W | 1 - 2 hrs |
| Inverter Battery Charging | appliances | 300 W | 1x | 300 W | 1 - 2 hrs |
Ratings are based on standard Bureau of Energy Efficiency (BEE) 3-star benchmarks. Newer 5-star inverter models consume 20% to 40% less electricity.
Connected Load vs Sanctioned Load vs Peak Load: What Every Indian Consumer Must Know
When examining an electricity bill from state Discoms such as Tata Power, Adani Electricity, BESCOM, MSEDCL, UPPCL, or Torrent Power, consumers frequently encounter terms like Sanctioned Load (or Contract Demand) in kW. Understanding how this differs from Connected Load and Peak Load is essential before installing rooftop solar.
1. Connected Load
Connected load is the theoretical maximum continuous power demand if every light, ceiling fan, air conditioner, pump, and kitchen appliance in your home were turned on simultaneously. In practice, homes operate with a diversity factor of 0.4 to 0.6, meaning only 40% to 60% of total connected load runs at any given moment.
2. Sanctioned Load
Sanctioned load is the maximum continuous power your electricity provider permits you to draw from the grid without paying penal demand charges. Under state net metering regulations, most Discoms cap your rooftop solar installation capacity at 80% to 100% of your sanctioned load. If your calculated solar requirement exceeds your sanctioned load, you must apply to your Discom for a load enhancement before commissioning.
3. Peak / Surge Load
Inductive motors — specifically in air conditioners, refrigerators, washing machines, and submersible water pumps — demand an instantaneous starting inrush current 1.5 to 3 times their steady running wattage. This surge lasts only 200 to 500 milliseconds, but your solar inverter must have sufficient surge handling capability (typically 200% for 5 seconds) to prevent safety shutdowns.
Practical Ways to Reduce Your Household Solar Load & Upfront Cost
Reducing your home energy demand before sizing a solar system is the most cost-effective decision you can make. Every 1 kW reduction in required solar capacity saves approximately ₹55,000 to ₹65,000 in upfront capital cost:
Switch to BLDC Ceiling Fans
Conventional induction motor ceiling fans consume 75 Watts. Modern Brushless DC (BLDC) ceiling fans deliver identical air delivery while consuming just 28 to 32 Watts — cutting fan power consumption by over 55%.
Upgrade to 5-Star Inverter Air Conditioners
Fixed-speed compressor ACs draw full wattage continuously and create massive startup surges. Variable-frequency inverter ACs modulate compressor speed to match room cooling demand, dropping steady running consumption to 600–900 Watts and virtually eliminating motor starting spikes.
Schedule Heavy Loads During Peak Solar Hours (10:00 AM – 3:00 PM)
Running washing machines, dishwashers, and water pumps during peak midday solar generation hours maximizes direct self-consumption, avoiding round-trip battery losses and export-import tariff differentials under gross metering or time-of-day tariffs.
Replace Resistance Water Heaters with Solar Water Heating or Heat Pumps
A standard 2 kW electric immersion geyser consumes 2 to 3 units per hour. Replacing electric resistance heating with dedicated rooftop solar thermal collectors or air-source heat pumps reduces heating power requirements by up to 70%.
State-Wise Electricity Tariffs & Monthly Solar Savings Benchmark
Domestic electricity tariffs across Indian states vary widely from ₹5.50 per unit in hydro-rich regions to over ₹9.50 per unit for higher consumption slabs in Maharashtra, West Bengal, and Karnataka. Higher tariffs yield faster capital payback on solar systems:
| State | Average Discom Tariff | 3 kW Monthly Yield | Est. Monthly Savings |
|---|---|---|---|
| Maharashtra | ₹8.8/unit | 338 units | ₹2,974/mo |
| Kerala | ₹7.6/unit | 344 units | ₹2,614/mo |
| Bihar | ₹7.5/unit | 344 units | ₹2,580/mo |
| Karnataka | ₹7.4/unit | 345 units | ₹2,553/mo |
| West Bengal | ₹7.3/unit | 323 units | ₹2,358/mo |
| Uttar Pradesh | ₹7.2/unit | 341 units | ₹2,455/mo |
| Rajasthan | ₹7.1/unit | 380 units | ₹2,698/mo |
| Telangana | ₹7.1/unit | 358 units | ₹2,542/mo |
| Andhra Pradesh | ₹6.9/unit | 358 units | ₹2,470/mo |
| Delhi | ₹6.8/unit | 333 units | ₹2,264/mo |
| Madhya Pradesh | ₹6.7/unit | 386 units | ₹2,586/mo |
| Punjab | ₹6.5/unit | 344 units | ₹2,236/mo |
| Tamil Nadu | ₹6.5/unit | 341 units | ₹2,217/mo |
| Haryana | ₹6.2/unit | 351 units | ₹2,176/mo |
| Gujarat | ₹5.8/unit | 366 units | ₹2,123/mo |
Continue planning
Inverter Size Calculator
Right VA rating for your load.
Solar Battery Backup Calculator
Battery Ah needed for backup hours.
Solar Panel Cost Calculator
Price and subsidy for your system size.
PM Surya Ghar Subsidy Calculator
Central & state rooftop solar subsidies.
Explore Rooftop Solar by State & City
Calibrated with state Discom tariffs, local net-metering policies, and PM Surya Ghar subsidies across India.
Browse Solar Guides by State
Top Solar MarketsFrequently asked questions
What is a solar load calculation and why does it matter?
It is the total electricity your appliances consume in a day measured in kilowatt-hours (kWh or units). This figure determines the exact solar panel capacity, inverter rating, and battery storage you need. Undersizing leads to high electricity bills, while oversizing leads to wasted capital expenditure.
What is the difference between connected load and peak load?
Connected load is the total wattage if all appliances ran at once. Peak load accounts for the starting surge current drawn by electric motors (compressors in ACs, refrigerators, and water pumps), which can be 1.5 to 3 times their running wattage.
How many units does a typical Indian home use per day?
A 1BHK apartment uses 4 to 6 units per day, a 2BHK uses 10 to 14 units per day, and a 3BHK with two air conditioners uses 18 to 24 units per day. Consumption rises during peak summer months.
How is inverter capacity in VA calculated from appliance wattage?
Inverter capacity in VA equals Total Running Watts divided by the Power Factor (typically 0.8 for homes with motors and fans), multiplied by a 1.25 safety factor. For example, a 1,600 Watt running load needs at least a 2,500 VA (2.5 kVA) inverter.
How much battery backup do I need for power cuts?
For a typical 400 Watt critical running load (fans, lights, Wi-Fi, TV), a 4-hour power cut requires roughly 1,600 Watt-hours of energy. Taking inverter losses and 60% depth of discharge into account, this requires one 150 Ah 12V tubular battery.
Does this calculator include the PM Surya Ghar subsidy?
Yes. The calculation applies the official central subsidy slabs under PM Surya Ghar Muft Bijli Yojana: ₹30,000 for 1 kW, ₹60,000 for 2 kW, and up to ₹78,000 for 3 kW and above.
Why should household appliances be listed individually in a load audit?
Listing appliances separately accounts for their distinct running cycles, duty hours, and inductive motor startup surges, ensuring the solar inverter and panel array are sized accurately without overpaying or tripping.
How should I account for air conditioner and pump motor startup surge?
Compressors, water pumps, and heavy motor appliances draw an instantaneous surge of 25% to 30% above their rated running wattage. Inverter capacity must be sized to absorb these peaks safely.
What system losses should be considered in solar load calculations?
A realistic design incorporates roughly 15% to 20% overall system losses, accounting for inverter DC-to-AC conversion efficiency, wire resistance, thermal derating, and dust soiling.