रूफटॉप सिमुलेटर और ब्लूप्रिंट

सोलर पैनल संख्या कैलकुलेटर Number of Solar Panels Calculator for Indian Homes

अपने मासिक बिजली बिल, खपत यूनिट, या उपलब्ध छत के माप के अनुसार जानें कि आपको कितने सोलर पैनल चाहिए। राज्य DISCOM टैरिफ और पीएम सूर्य घर सब्सिडी पर आधारित गणना।

Calculation Mode
₹
₹500/mo ₹10,000/mo ₹25,000/mo
units
50 units (1 BHK) 400 units (3 BHK) 1,200+ units (ACs)
kW
1 kW 3 kW (Most Popular) 10 kW
ft
ft
kW
₹ /unit
राज्य औसत DISCOM दर: ₹/unit Sun Hours: PSH
100% छत खुली रहेगी

Solar Panel Layout & Sizing Engine

NASA PSH Data & DISCOM Tariff Engine

%
1. Rooftop Dimensions & Module Wattage Analyzed
2. Physical Aspect Ratio & Matrix Grid Sized
3. Shadow-Free Spacing & Dead Load Verified
4. Visual Array Layout & Generation Output Ready

रूफटॉप सोलर लेआउट व पैनल ब्लूप्रिंट सिमुलेटर

बाईं तरफ इनपुट चुनें और 2D एरे ब्लूप्रिंट जनरेट करने के लिए "पैनल संख्या कैलकुलेट करें" पर क्लिक करें।

Exact Module Count

440W, 540W & 580W TOPCon high-efficiency modules.

Shadow Clearance

1.25x inter-row pitch and 2.5 ft perimeter maintenance walkways.

Dead Load Check

IS 456 standard RCC slab verification (~15-18 kg/m²).

PM Surya Ghar

Full DBT subsidy calculation up to ₹78,000 + state top-up.

इंजीनियरिंग नियम और आधार डेटा अपडेट हुआ: 18 Nov 2026
  • छत की जगह प्रति kW लगभग 100 वर्ग फुट छाया-मुक्त जगह मानती है, जिसमें पंक्तियों के बीच धूप का अंतर और 2.5 फुट चौड़ा रास्ता शामिल है।
  • पैनल वज़न प्रति पैनल लगभग 25 kg माना गया है, जिससे छत पर 15 से 20 kg/m² का डेड लोड पड़ता है, जो भारतीय RCC छत के लिए पूरी तरह सुरक्षित है।
  • मासिक उत्पादन राज्य के सौर घंटों (PSH) और 78% परफॉरमेंस रेशियो के आधार पर आंका गया है।
  • सब्सिडी पीएम सूर्य घर योजना के अनुसार: 2 kW तक ₹30,000/kW, तीसरे kW पर ₹18,000, अधिकतम केंद्रीय सहायता ₹78,000।

मासिक बिल के अनुसार ज़रूरी पैनल

Standard residential sizing table based on benchmark 540W modules, 440W modules, and 580W high-power modules calibrated with national average tariffs.

मासिक बिल Monthly Units System Size पैनल (540W) Panels (440W) Panels (580W) छत की जगह PM Surya Ghar Subsidy Monthly Savings
₹1,500 214 units 2 kW 4 5 4 200 sq ft ₹60,000 ₹1,540
₹2,500 357 units 3.5 kW 7 8 7 350 sq ft ₹78,000 ₹2,695
₹4,000 571 units 5.5 kW 11 13 10 550 sq ft ₹78,000 ₹4,235
₹6,000 857 units 8 kW 15 19 14 800 sq ft ₹78,000 ₹6,160
₹8,000 1143 units 10 kW 19 23 18 1,000 sq ft ₹78,000 ₹7,700
₹12,000 1714 units 10 kW 19 23 18 1,000 sq ft ₹78,000 ₹7,700

राष्ट्रीय-औसत टैरिफ और सन आवर्स पर आधारित। सटीक आंकड़ों के लिए ऊपर अपना राज्य चुनें।

भारत के प्रमुख राज्यों में सोलर उत्पादन और ज़रूरी पैनल

भौगोलिक स्थिति और धूप के घंटों (PSH) के कारण विभिन्न राज्यों में उत्पादन अलग होता है। यहाँ 3 kW सिस्टम का राज्यवार तुलनात्मक विवरण है:

State / Union Territory Sun Hours (PSH) Avg DISCOM Tariff 3kW Panel Count (540W) Monthly Generation Monthly Bill Savings State Top-Up Support
गुजरात 5.22 hrs/day ₹5.8/unit 6 panels 366 units ₹2,123 Surya Gujarat Yojana
महाराष्ट्र 4.82 hrs/day ₹8.8/unit 6 panels 338 units ₹2,974 Central Subsidy Only
राजस्थान 5.41 hrs/day ₹7.1/unit 6 panels 380 units ₹2,698 Mukhyamantri Nishulk Bijli Yojana Solar Top-Up
उत्तर प्रदेश 4.86 hrs/day ₹7.2/unit 6 panels 341 units ₹2,455 UP State Solar Policy Top-Up Subsidy (UPNEDA)
कर्नाटक 4.91 hrs/day ₹7.4/unit 6 panels 345 units ₹2,553 Central Subsidy Only
तमिलनाडु 4.86 hrs/day ₹6.5/unit 6 panels 341 units ₹2,217 Tamil Nadu State Solar Top-Up Scheme (TNGECL / TEDA)
दिल्ली 4.75 hrs/day ₹6.8/unit 6 panels 333 units ₹2,264 Delhi Solar Policy 2024–2027 (Capital Subsidy + Gbi)
केरल 4.90 hrs/day ₹7.6/unit 6 panels 344 units ₹2,614 Central Subsidy Only
मध्य प्रदेश 5.50 hrs/day ₹6.7/unit 6 panels 386 units ₹2,586 Central Subsidy Only
पश्चिम बंगाल 4.60 hrs/day ₹7.3/unit 6 panels 323 units ₹2,358 WBSEDCL State Rooftop Solar Top-Up Scheme

भारत में प्रमुख सोलर पैनल ब्रांड्स और सेल तकनीक (2026)

नवीन एवं नवीकरणीय ऊर्जा मंत्रालय (MNRE) की ALMM लिस्ट के तहत प्रमाणित प्रमुख भारतीय सोलर कंपनियों की तुलना:

Manufacturer Brand Model Wattage Cell Technology Module Efficiency Tier-1 Rating Approx. Price / Panel
Adani Solar 545W TOPCon 545W TOPCon 21.2% Tier-1 ₹13,800
Panasonic 545W TOPCon 545W TOPCon 21.4% Tier-1 ₹14,500
Tata Power Solar 535W Mono PERC 535W PERC 20.7% Tier-1 ₹13,500
Vikram Solar 540W Mono PERC 540W PERC 20.8% Tier-1 ₹12,200
Waaree 540W Mono PERC 540W PERC 20.9% Tier-1 ₹12,000
Goldi Solar 550W TOPCon 550W TOPCon 21.3% ALMM Approved ₹12,800
Luminous 540W Mono PERC 540W PERC 20.5% ALMM Approved ₹13,000
RenewSys 545W Mono PERC 545W PERC 20.9% ALMM Approved ₹11,800
Saatvik 540W Mono PERC 540W PERC 20.6% ALMM Approved ₹11,500

घर के लिए कितने सोलर पैनल चाहिए: संपूर्ण इंजीनियरिंग गाइड

सोलर तकनीकी अनुसंधान दल द्वारा संकलित · MNRE दिशानिर्देशों और IS 456 / IS 875 मानकों के अनुसार प्रमाणित

1. The Exact Mathematical Formula for Solar Panel Sizing

Solar panel calculation is not a guessing game. It is determined by your household's actual electrical consumption, the average daily sunlight available at your latitude, and the wattage of modern photovoltaic modules. Professional solar engineers in India follow this 5-step method:

Core Sizing Equations

Step A: Daily Energy Requirement
Daily Units (kWh) = Monthly Electricity Units Consumed ÷ 30 days

Step B: Required System Capacity (kW)
System kW = Daily Units ÷ (Peak Sun Hours × System Performance Ratio)

Step C: Number of Panels Needed
Panel Count = (System kW × 1,000 Watts) ÷ Rated Wattage per Panel

In India, solar irradiance yields between 4.2 and 5.5 Peak Sun Hours (PSH) per day depending on whether you are located in northern, central, western, or southern states. System Performance Ratio (PR) is standardly calibrated at 0.78 (78%), which accounts for real-world environmental factors including high ambient summer temperatures, dust accumulation on glass, inverter conversion efficiency (typically 97%), and DC/AC cabling resistance.

For example, if your home in Maharashtra or Gujarat consumes 360 units per month:

  • Daily consumption = 360 ÷ 30 = 12 units (kWh/day).
  • Required DC system size = 12 ÷ (4.8 PSH × 0.78 PR) = 3.20 kW.
  • Recommended system size rounded to the nearest standard inverter rating = 3.0 kW to 3.3 kW.
  • Number of 540W Mono PERC panels needed = 3,200W ÷ 540W = 5.92, rounded up to 6 panels.

2. Choosing Between 440W, 540W, and 580W Solar Modules

Until 2021, Indian residential installations primarily used 330W polycrystalline panels. Today, the Indian market has decisively shifted to high-output half-cut Monocrystalline PERC and N-Type TOPCon modules ranging from 535W to 580W.

440W–450W Modules

Dimensions: 1.95m × 1.04m (approx 21 sq ft). Best suited for small or complex roofs with narrow spaces and multiple obstructions.

540W–550W Modules (Standard)

Dimensions: 2.27m × 1.13m (approx 27.5 sq ft). The undisputed industry standard in India. Offers the lowest balance-of-system cost per watt.

580W+ TOPCon Modules

Dimensions: 2.38m × 1.13m (approx 29 sq ft). Next-generation N-Type technology delivering higher generation during peak summer heat.

Choosing higher-wattage modules reduces the total number of mounting brackets, aluminum rails, mid-clamps, end-clamps, and rooftop penetrations. For a 3kW system, choosing 540W modules requires only 6 panels, whereas older 330W panels would have required 9 to 10 panels, significantly increasing structural hardware and installation labor.

3. Shadow-Free Roof Space & Inter-Row Pitch Clearance

A common misconception among homeowners is assuming that their entire terrace area can be covered with solar panels. In reality, you must distinguish between gross roof area and usable shadow-free roof area:

  • The 100 Sq Ft Rule: In India, each 1 kW of rooftop solar requires approximately 90 to 100 square feet of shadow-free area on flat reinforced concrete (RCC) terraces. For a standard 3 kW system, you need roughly 300 square feet of unobstructed space.
  • Row-to-Row Inter-Pitch Spacing: Solar panels in India are installed with a southern tilt of 15° to 25° (matching your city's latitude) to maximize year-round solar capture. Because tilted panels cast a northern shadow behind them, consecutive rows must be separated by 0.8 to 1.2 meters. Placing rows too close together causes self-shading during low-angle winter months, drastically reducing power generation.
  • Mandatory Maintenance Walkways: Indian dust conditions necessitate cleaning panels every 10 to 15 days with water. Quality solar installations always leave a 2.5 to 3-foot perimeter corridor along parapet walls and between module tables to provide safe technician access without walking on glass.

4. Can Your Roof Bear the Weight? Structural Dead Load Analysis

One of the most frequent questions from homeowners is whether placing heavy solar panels and mounting structures will damage their roof slab.

A standard 540W framed glass panel weighs approximately 25 to 27 kg. For a 3 kW system consisting of 6 panels, the total module weight is about 150 to 160 kg. When you add hot-dip galvanized mounting structures and concrete ballast blocks, the total system weight is roughly 250 to 300 kg distributed across 300 square feet.

Structural Safety Benchmark (IS 456 Standards):

Standard residential reinforced cement concrete (RCC) roofs in India are engineered to support a minimum live load of 150 to 200 kg per square meter (approx 15 to 20 kg/sq ft). A rooftop solar installation exerts a dead load of only 15 to 20 kg per square meter (1.5 to 2.0 kg/sq ft). This means rooftop solar consumes less than 12% of the slab's rated structural load capacity, making it completely safe for sound residential buildings.

5. Solar Panel Capacity Guide for Indian Households

1 BHK Flat / Small Independent House (1 kW to 2 kW)

Typical Consumption: 100–180 units/month. Appliance mix: LED lights, ceiling fans, television, refrigerator, and 0.5 HP water pump. Panels needed: 2 to 4 modules (540W). Roof space required: 100–200 sq ft.

2 BHK to 3 BHK Home (3 kW — Most Popular)

Typical Consumption: 250–400 units/month. Appliance mix: All basic appliances plus one 1.5-ton 5-star inverter AC and washing machine. Panels needed: 6 modules (540W). Roof space required: 300 sq ft. Receives the full maximum central subsidy of ₹78,000 under PM Surya Ghar.

3 BHK to 4 BHK Home with 2 Air Conditioners (5 kW)

Typical Consumption: 500–700 units/month. Appliance mix: Multiple inverter ACs, induction cooker, microwave, microwave oven, and water geysers. Panels needed: 9 to 10 modules (540W). Roof space required: 500 sq ft.

Large Villa / Joint Family Bungalow with EV (8 kW to 10 kW)

Typical Consumption: 900–1,500 units/month. Appliance mix: 3+ air conditioners, electric vehicle home charger, dishwasher, heat pump water heater. Panels needed: 15 to 19 modules (540W). Roof space required: 800–1,000 sq ft.

6. PM Surya Ghar Subsidy and Net Metering in India

The Government of India launched the PM Surya Ghar Muft Bijli Yojana to provide direct financial assistance for residential rooftop installations. The central subsidy structure is defined as:

  • 1 kW System: ₹30,000 central subsidy.
  • 2 kW System: ₹60,000 central subsidy.
  • 3 kW and above: ₹78,000 flat central subsidy cap.

Several state governments provide additional top-up incentives. For example, Assam provides up to ₹45,000 in additional state support, Uttar Pradesh offers up to ₹30,000, and Delhi provides generation-based solar incentives. You can verify and apply directly through the official National Portal (pmsuryaghar.gov.in) and the Ministry of New and Renewable Energy (mnre.gov.in).

आगे की योजना बनाएं

सोलर पैनल कीमत कैलकुलेटर

पूरी कीमत और सब्सिडी का ब्योरा।

Calculate Now

रूफटॉप लोड कैलकुलेटर

जांचें कि आपकी छत वज़न झेल सकती है।

जल्द आ रहा है

सोलर पैनल प्राइस लिस्ट

पैनल ब्रांड और कीमतों की तुलना करें।

जल्द आ रहा है

क्षेत्रीय सोलर हब

राज्य एवं शहर अनुसार रूफटॉप सोलर गाइड

राज्य DISCOM बिजली टैरिफ, स्थानीय नेट-मीटरिंग नियमों और पीएम सूर्य घर सब्सिडी अनुसार कैलिब्रेटेड।

अक्सर पूछे जाने वाले सवाल

3kW सिस्टम के लिए मुझे कितने सोलर पैनल चाहिए?

स्टैंडर्ड 540W पैनल के साथ, 3kW सिस्टम को 6 पैनल चाहिए (3000W ÷ 540W, राउंड अप)। छोटे 440W पैनल के साथ, समान क्षमता के लिए 7 पैनल चाहिए होंगे।

क्या पैनल वॉटेज इस बात को प्रभावित करता है कि मुझे कितने पैनल चाहिए?

हां — ज़्यादा वॉटेज वाले पैनल (580W) को समान कुल सिस्टम साइज़ के लिए कम वॉटेज वाले पैनल (440W) से कम यूनिट चाहिए होते हैं, हालांकि कुल ज़रूरी छत की जगह लगभग समान रहती है क्योंकि ज़्यादा वॉट वाले पैनल आमतौर पर फिज़िकली भी बड़े होते हैं।

एक सोलर पैनल का वज़न कितना होता है?

एक सामान्य फ्रेम्ड ग्लास सोलर पैनल का वज़न साइज़ और वॉटेज के अनुसार 22–28 kg होता है। 6-पैनल (3kW) सिस्टम के लिए, माउंटिंग स्ट्रक्चर और बैलास्ट को छोड़कर लगभग 150 kg कुल वज़न मानें।

क्या छोटी छत पर सोलर पैनल फिट हो सकते हैं?

1kW सिस्टम को सिर्फ लगभग 100 वर्ग फुट चाहिए, इसलिए छोटे घरों में भी आमतौर पर एक अच्छे सिस्टम के लिए काफी छत की जगह होती है। हमारा रूफटॉप लोड कैलकुलेटर पुष्टि कर सकता है कि आपकी छत सुरक्षित रूप से वज़न झेल सकती है।

क्या मुझे ज़्यादा छोटे पैनल चुनने चाहिए या कम बड़े पैनल?

ज़्यादातर घरों के लिए, कम हाई-वॉटेज पैनल माउंटिंग पॉइंट्स और वायरिंग की जटिलता कम करते हैं, इंस्टॉलेशन कॉस्ट थोड़ी घटाते हैं — लेकिन कुल सिस्टम कीमत में अंतर आमतौर पर छोटा होता है।

पैनल संख्या और सिस्टम साइज़ (kW) में क्या फर्क है?

सिस्टम साइज़ (kW) आपकी बिजली खपत के आधार पर ज़रूरी कुल क्षमता है। पैनल संख्या बस वह क्षमता हर पैनल की वॉटेज से भाग देकर निकाली जाती है — अगर आप ज़्यादा वॉटेज चुनें तो समान kW साइज़ के लिए कम पैनल चाहिए।

सोलर पैनलों की संख्या की गणना में किस वाट के पैनल माने गए हैं?

गणना में 2026 के मानक 540W–550W मोनो पर्क और टॉपकॉन पैनलों का उपयोग किया गया है। अधिक वाट के पैनल लगाने से कम पैनल और कम माउंटिंग स्ट्रक्चर की जरूरत होती है।

टिल्ट स्पेसिंग क्या है और पंक्तियों के बीच जगह छोड़ना क्यों जरूरी है?

दक्षिण दिशा की ओर झुके सोलर पैनलों की परछाई पीछे की ओर पड़ती है। सर्दियों में धूप के समय पीछे की पंक्ति पर छाया न पड़े, इसके लिए पंक्तियों के बीच 0.8 से 1.2 मीटर की जगह छोड़ना आवश्यक है।

छत की रुकावटों (जैसे पानी की टंकी) से पैनल लेआउट पर क्या असर पड़ता है?

पानी की टंकी, सीढ़ी के कमरे और पैरापेट की दीवारें छाया बनाती हैं। आमतौर पर 1 kW के लिए 100 वर्ग फीट जगह चाहिए, लेकिन रुकावटों वाली छत पर छाया-मुक्त जगह पाने के लिए 120-130 वर्ग फीट की आवश्यकता हो सकती है।

इस अनुमान पर भरोसा करने से पहले

यह कैलकुलेटर आपके इनपुट्स और सामान्य अनुमानों के आधार पर प्रारंभिक योजना सीमा प्रदान करता है। यह वास्तविक साइट विजिट, शैडो एनालिसिस, डिस्कॉम स्वीकृति या वेंडर के अंतिम कोटेशन का विकल्प नहीं है।

कैलकुलेटर अंतिम कोटेशन नहीं है। वेंडर के लिखित कोट में सोलर पैनल व इनवर्टर मॉडल, माउंटिंग स्ट्रक्चर, सुरक्षा उपकरण, टैक्स, नेट-मीटरिंग कार्य, वारंटी और प्रोजेक्ट पूरा होने की समयसीमा स्पष्ट लिखी होनी चाहिए।

अगला कदम: सुझाई गई क्षमता और बजट को वेंडर के लिखित कोटेशन से मिलाएं।

सोलर कोट जाँचें →