BEE & PM Surya Ghar Sizing

Solar Panels for AC Calculator: 1 Ton & 1.5 Ton

Calculate the exact solar panels, system kW, PM Surya Ghar subsidy, and monthly electricity bill savings required to run your air conditioner in India.

PM Surya Ghar Subsidy Guide
Step 1 / 6
Step 1 / 6

Select Your State & District

Electricity tariffs and state subsidy grants depend directly on your DISCOM and local solar irradiance.

Please select your state before proceeding

Electricity Distribution Company (DISCOM)
₹ /u

Air Conditioner (AC) Sizing & Usage Pattern

Tell us what you know. Our engineering engine derives panel wattage, sun hours, and sizing behind the scenes.

8 hrs/day
kW
₹ /unit

Terrace Structure & System Preferences

Select your mounting structure to retain full terrace usability for walking and household activities.

Please select an option
Please select an option
Please select an option
Please select your terrace and system preferences above before proceeding.

Solar Sizing for Air Conditioner Loads

Inverter Compressor Surge & Daily Run-Time Sizing

%
1. Sizing AC wattage, compressor surge & run-time kWh...
2. Modeling daily generation units & solar array kW needed...
3. Calculating grid-tie net metering offset & DISCOM savings...
4. Applying PM Surya Ghar subsidy & calculating net investment...

Unlock Your Detailed Solar Report

Enter your 10-digit mobile number to view the itemized price breakdown, PM Surya Ghar subsidy deduction, and engineering report.

+91

6-digit SMS code sent to: +91

Auto-detecting SMS OTP...
Clipboard OTP:
Resend code in s

Calculation based on MNRE PM Surya Ghar subsidy guidelines. By continuing, you agree to receive customized solar quotes.

Engineering assumptions & methodology Data updated: 18 Nov 2026
  • AC running wattage and compressor surge are aligned with Bureau of Energy Efficiency (BEE) Indian Seasonal Energy Efficiency Ratio (ISEER) benchmark standards.
  • System sizing factors in state-specific solar insolation (peak sun hours) and an engineering performance ratio of 78% for dust, temperature, and wiring losses.
  • PM Surya Ghar: Muft Bijli Yojana central subsidy is calculated at ₹30,000/kW up to 2 kW, plus ₹18,000 for the 3rd kW (capped at ₹78,000 for residential systems).
  • Off-grid battery calculations assume a 48V DC bus configuration with 80% usable Depth of Discharge (DoD) for Lithium and 60% DoD for Tall Tubular batteries.
  • Inverter sizing incorporates a 0.8 power factor and locked rotor compressor starting surges (LRA) to prevent breaker tripping.

Panels Needed by AC Size (8 hrs/day)

Technical benchmark based on 8 hours daily operation, 540W high-efficiency Mono PERC / TOPCon solar panels, and official PM Surya Ghar subsidy rates.

AC Type & Capacity Running Draw Daily Units (8h) System Size 540W Panels Turnkey Cost Central Subsidy Net Investment Monthly Saving
AC 1 Ton (3 Star) 1100 W 8.8 kWh 2.5 kW 5 ₹₹1,42,500 ₹₹69,000 ₹₹73,500 ₹₹1,951/mo
AC 1 Ton Inverter (5 Star) 850 W 6.8 kWh 2 kW 4 ₹₹1,14,000 ₹₹60,000 ₹₹54,000 ₹₹1,561/mo
AC 1.5 Ton (3 Star) 1700 W 13.6 kWh 4 kW 8 ₹₹2,20,000 ₹₹78,000 ₹₹1,42,000 ₹₹3,122/mo
AC 1.5 Ton Inverter 1300 W 10.4 kWh 3 kW 6 ₹₹1,65,000 ₹₹78,000 ₹₹87,000 ₹₹2,342/mo
AC 1.5 Ton Inverter (5 Star) 1050 W 8.4 kWh 2.5 kW 5 ₹₹1,42,500 ₹₹69,000 ₹₹73,500 ₹₹1,951/mo
AC 2 Ton 2100 W 16.8 kWh 5 kW 10 ₹₹2,60,000 ₹₹78,000 ₹₹1,82,000 ₹₹3,903/mo
AC 2 Ton Inverter (5 Star) 1550 W 12.4 kWh 3.5 kW 7 ₹₹1,92,500 ₹₹78,000 ₹₹1,14,500 ₹₹2,732/mo

Based on 8 hours of daily use and 540W panels — your exact hours may differ. Subsidies apply to residential rooftop systems under the PM Surya Ghar: Muft Bijli Yojana.

How to Calculate Solar Panels for an AC: The Engineering Formula

1. Calculate Daily Energy Consumption (kWh)

Air conditioner power consumption depends on running wattage and daily usage hours. A standard 1.5-ton inverter AC averages approximately 1,300 Watts during steady cooling. If run for 8 hours daily:

Daily Units = (1,300 W × 8 hours) ÷ 1,000 = 10.4 kWh (units)/day
Monthly Units = 10.4 kWh × 30 days = 312 units/month

2. Determine Solar System Capacity (kW)

In Indian climatic conditions, rooftop solar generates approximately 4.7 Peak Sun Hours (PSH) per day at a 78% Performance Ratio (PR) accounting for dust, temperature derating, and wiring loss:

Required kW = 312 units ÷ (30 days × 4.7 PSH × 0.78 PR) = 2.83 kW
Commercial Standard Recommended = 3.0 kW Solar System

Panel Count for 3.0 kW Solar System:

3,000 Watts ÷ 540 Watts per panel = 5.55 → Exactly 6 high-efficiency Mono PERC / TOPCon half-cut panels, requiring approximately 300 square feet of shadow-free rooftop space.

Running AC on Solar: Grid-Tied Net Metering vs Off-Grid Battery Bank

Understanding the technical and financial differences between grid-tied solar export banking and high-capacity battery storage for cooling loads in India.

Grid-Tied Net Metering (Recommended for 95% of Homes)

  • Direct Solar Cooling: Between 11:00 AM and 03:00 PM, peak solar generation directly matches peak afternoon air conditioning cooling loads without battery losses.
  • Nighttime Solar Banking: Excess electricity exported during daytime generates credit units on your DISCOM electricity bill, which offsets night AC consumption unit-for-unit.
  • Lowest Cost & Zero Maintenance: Requires no expensive batteries that need replacement every 4 to 8 years. Eligible for full PM Surya Ghar subsidies.

Off-Grid Battery System (For Remote Areas & Frequent Outages)

  • Massive Storage Requirement: Running a 1.5-ton AC for 8 night hours requires 10 to 12 kWh of stored energy. This demands a 48V 300Ah battery bank (over 400 kg in tubular lead-acid).
  • High Inrush Current: Requires a heavy-duty 5 kVA pure sine wave inverter to absorb compressor starting surges (LRA) without tripping circuit breakers.
  • Higher Capital Investment: Upfront system cost is 2x to 3x higher than on-grid solar due to battery packs and does not qualify for PM Surya Ghar subsidies under standard discom net metering rules.

State-Wise Solar AC Generation & DISCOM Bill Savings

Comparison for a standard 3 kW residential rooftop solar system (ideal for a 1.5-ton AC) across Indian states based on DISCOM domestic tariffs and annual peak sun hours.

State Peak Sun Hours (PSH) Average DISCOM Tariff Monthly Generation Monthly Saving Solar Policy
Maharashtra 4.82 hrs/day ₹8.8/unit 338 units ₹₹2,978/mo Net Metering
Gujarat 5.22 hrs/day ₹5.8/unit 366 units ₹₹2,125/mo Net Metering
Rajasthan 5.41 hrs/day ₹7.1/unit 380 units ₹₹2,696/mo Net Metering
Uttar Pradesh 4.86 hrs/day ₹7.2/unit 341 units ₹₹2,456/mo Net Metering
Delhi 4.75 hrs/day ₹6.8/unit 333 units ₹₹2,267/mo Net Metering
Karnataka 4.91 hrs/day ₹7.4/unit 345 units ₹₹2,551/mo Net Metering
Tamil Nadu 4.86 hrs/day ₹6.5/unit 341 units ₹₹2,218/mo Net Billing
West Bengal 4.60 hrs/day ₹7.3/unit 323 units ₹₹2,357/mo Net Metering

Tariffs and solar radiation reflect database records for state capital cities. Individual municipal discom tiers and consumption slabs may vary slightly.

Practical Engineering Tips to Maximize AC Efficiency on Solar Power

1. Optimal Thermostat (24°C - 26°C)

Bureau of Energy Efficiency (BEE) guidelines indicate that each degree Celsius increase in thermostat setting reduces AC power consumption by 6%. Setting your AC to 24°C rather than 18°C saves approximately 36% of daily electricity.

2. Pre-Cooling During Peak Solar Hours

Cool your rooms between 12:00 PM and 03:00 PM when rooftop solar generation reaches peak output. Storing thermal cooling in insulated walls and furniture reduces cooling demand during late afternoon and evening hours.

3. Regular Bi-Weekly Filter Cleaning

In dusty Indian urban environments, clogged indoor AC mesh filters restrict airflow and force compressors to work 10% to 15% harder. Rinsing mesh filters every two weeks maintains smooth airflow and low wattage draw.

4. Condenser Shading & Airflow

Ensure your outdoor condenser unit is placed in a well-ventilated area protected from direct afternoon heat radiation. Good airflow enables faster refrigerant heat dissipation, reducing compressor strain.

5. Solar Panel Dust & Soiling Care

Dust accumulation on rooftop solar panels causes 8% to 12% generation loss in dry summer months. Washing panels with clean water in the early morning twice a month ensures full rated output during peak AC hours.

6. Upgrade to 5-Star Inverter Models

Upgrading an older 3-star fixed-speed AC to a 5-star inverter AC lowers required solar system size by 0.5 to 0.8 kW, saving ₹30,000 to ₹45,000 on upfront solar installation costs.

Authoritative Energy & Solar Portals

Explore official government guidelines, standards, and subsidy applications.

Continue planning your solar installation

Solar Load Calculator

Add all your home appliances for comprehensive system sizing.

Calculate Now

Number of Solar Panels Calculator

Panel count, roof blueprint, and layout planner.

Calculate Now

Solar Panel Cost Calculator

Comprehensive price quotation, state top-ups, and bank EMI.

Calculate Now
Regional Solar Hubs

Explore Rooftop Solar by State & City

Calibrated with state Discom tariffs, local net-metering policies, and PM Surya Ghar subsidies across India.

Frequently Asked Questions on Running AC on Solar in India

How many solar panels do I need to run a 1.5 ton AC in India? ▾

To run a standard 1.5-ton 3-star AC for 8 hours daily, you need a 3 kW solar system, which consists of 6 solar panels of 540 Watts each. A 1.5-ton 5-star inverter AC is more efficient and can be powered by a 2.5 kW system (5 panels of 540W). This requires approximately 250 to 300 square feet of shadow-free rooftop area.

Can solar panels run an air conditioner directly without batteries? ▾

Yes, through an on-grid (grid-tied) solar system with net metering. During daylight hours, electricity generated by your rooftop solar panels powers your AC directly. Any excess electricity is exported to the local electricity grid. If cloud cover temporarily reduces generation, the remaining power is automatically drawn from the grid without interruption.

Do inverter ACs need fewer solar panels than non-inverter ACs? ▾

Yes. Inverter ACs use variable-speed brushless DC (BLDC) compressors that modulate cooling output once the room temperature stabilizes. A 1.5-ton non-inverter AC constantly draws around 1,700 Watts, whereas a 5-star inverter AC reduces consumption to 800–1,100 Watts in steady state. This lowers total daily unit consumption by 25% to 35%, requiring fewer solar panels.

How does running an AC at night work with solar power? ▾

Solar panels produce power only during daylight hours. To cover night AC consumption, homeowners with grid-tied systems rely on net metering banking: surplus solar units exported during the afternoon generate credit units on your DISCOM bill that offset nighttime grid consumption. For areas without reliable grid power, an off-grid system with a 48V lithium or tubular battery bank is required.

Is it worth going completely off-grid with batteries just to power an AC? ▾

For most urban and semi-urban Indian households connected to a reliable grid, on-grid net metering is substantially more cost-effective. An off-grid battery bank sized to run a 1.5-ton AC for 6 to 8 hours requires roughly 300 to 400 Ah at 48V (four large batteries or a 15–20 kWh lithium pack) and a 5 kVA inverter to handle compressor startup surge, increasing upfront installation cost by 2x to 3x compared to grid-tied solar.

Can I get the PM Surya Ghar ₹78,000 subsidy for an AC solar system? ▾

Yes. Rooftop solar systems installed on residential homes are eligible for the central PM Surya Ghar: Muft Bijli Yojana subsidy regardless of which household appliances you operate. A 1 kW system receives ₹30,000, a 2 kW system receives ₹60,000, and systems of 3 kW or higher receive the maximum subsidy of ₹78,000.

What size inverter is needed to handle AC starting compressor surge (LRA)? ▾

Fixed-speed non-inverter air conditioners have a high starting inrush current (Locked Rotor Amperes or LRA) that is 3 to 4 times their rated running wattage for a split second. A 1.5-ton non-inverter AC requires at least a 5,000 VA (5 kVA) inverter. In contrast, modern inverter AC compressors start slowly with soft-start electronic circuitry, allowing operation on a 3,500 VA inverter.

How much monthly electricity bill can I save by running an AC on solar? ▾

A 1.5-ton AC operated for 8 hours daily consumes approximately 10 to 12 units (kWh) per day, or 300 to 360 units per month. At typical residential DISCOM tariffs of ₹7 to ₹9 per unit in states like Maharashtra, Delhi, Uttar Pradesh, and Karnataka, monthly electricity savings range between ₹2,100 and ₹3,200, translating to annual savings of ₹25,000 to ₹38,000.

Before you rely on this estimate

This calculator produces a planning range from your inputs and the assumptions shown on the page. It cannot replace a site visit, roof-shade survey, Discom approval or supplier quotation.

A calculator is not a quotation. A written quote should separately state the module and inverter model, mounting structure, protection equipment, taxes, net-metering work, warranty and completion timeline.

Next step: match the suggested capacity and budget against the written quote scope.

Check a solar quote →